Home » Quality » Inspection Test Plan
.................................................................................
 
FINISHED CABLE INSPECTION        
A. Routine Tests          
  1) Conductor Resistance Double Kelvin Bridge 100% As per IS & BS Standards. Review by Client
    Digital Ohm meter     Review by Client
  2) High Voltage Test High voltage tester 100% As per IS & BS Standards. Review by Client
  3) Volume resistivity Insulation resistance meter   As per IS & BS Standards. Review by Client
  4) Dimensional Check vernier calliper 100% As per IS & BS Standards. Review by Client
  5) Thickness of insulation & Jacket vernier calliper 100% As per IS & BS Standards. Review by Client
  6) Insulation Resistance constant Insulation resistance meter 100% As per IS & BS Standards. Review by Client
  7) Armour resistance test (For Mining Cable) Micro Ohm Meter 100% As per IS & BS Standards. Review by Client
B. Acceptance tests          
  1) Annealing test on Copper. Tensile testing m / c per core As per IS-8130 Witness by Client
  2) Conductor diameter micrometer per core As per IS-8130 Witness by Client
  3) Conductor resistance Electrical Test / Digital micro ohm meter 100% As per IS-8130 Witness by Client
  4) Thickness of Insul. / sheath measurement per core As per IS & BS Standards. Witness by Client
  5) High Voltage Test at room temp Water tank, HV tester As per IS As per IS & BS Standards. Witness by Client
  6) Tensile strength of PVC / insulation / sheath Tensile testing m / c As per IS As per IS & BS Standards. Witness by Client
  7) Elongation of PVC / insulation / sheath Tensile testing m / c Do As per IS & BS Standards. Witness by Client
  8) Insul. resistance Test I.R. Tester Do As per IS & BS Standards. Witness by Client
  9) Flammability Test Flammability Chamber Do As per IS & BS Standards. Witness by Client
C. Type Tests          

1) Annealing test on Copper. Tensile testing m / c per core As per IS-8130 Review by Client
  2) Conductor diameter micrometer per core As per IS-8130 Review by Client
  3) Conductor resistance Electrical Test / Digital micro ohm meter 100% As per IS-8130 Review by Client
  4) Thickness of Insul. / sheath measurment per core As per IS & BS Standards. Review by Client
  5) High Voltage Test at room temp Water tank, HV tester As per IS As per IS & BS Standards. Review by Client
   6) Tensile strength of PVC / insulation / sheath Tensile testing m / c As per IS As per IS & BS Standards. Review by Client
  7) Elongation of PVC / insulation / sheath Tensile testing m / c Do As per IS & BS Standards. Review by Client
  8) Shrinkage test on PVC / insulation / sheath Oven Scales Do As per IS & BS Standards. Review by Client
  9) Hot deformation test for insulation / sheath Hot deformation test Do As per IS & BS Standards. Review by Client
    appartus, test apparatus, oven     Review by Client
  10) Ageing test for insulation / sheath Oven tensile testing m / c Do As per IS & BS Standards. Review by Client
  11) Loss of mass test for insulaion / sheath oven, weighing Do As per IS & BS Standards. Review by Client
  12)Thermal Stability Test for insulation / sheath Stability oven Do As per IS & BS Standards. Review by Client
  13) Insul.resistance Test I.R.Tester Do As per IS & BS Standards. Review by Client
  14) Test for armour       Review by Client
  - wire dia / strip size vernier / micrometer Do IS : 3975 Review by Client
  - Tensile test tensile tester meter Do IS : 3975 Review by Client
  - Elongation test tensile tester meter Do IS : 3975 Review by Client
  - Resistivity test of armour resistance meter Do IS : 3975 Review by Client
  - Mass of zinc coating Chemical Do IS : 3975 Review by Client
  15) Flammability Test Flammability Chamber Do As per IS & BS Standards. Review by Client